Efficient and accurate testing of an EMC compliance chamber using an ultrawideband measurement system

By: Novotny, D.R.; Johnk, R.T.; O'Hara, T.J.; Taylor, M.; Weil, C.M.;

2001 / IEEE / 0-7803-6569-0

Description

This item was taken from the IEEE Conference ' Efficient and accurate testing of an EMC compliance chamber using an ultrawideband measurement system ' This paper summarizes a joint NIST-Industry measurement effort. The purpose of this effort was to use a NIST-developed ultrawideband measurement system to assess the performance improvement of a ferrite tile anechoic chamber after a partial retrofit. Measurements were performed in the 30-1200 MHz frequency range before and after treatments were applied and excellent results were obtained. The system exhibited good sensitivity and the results highlight the effects of various retrofitting treatments. The effort also demonstrates that the NIST ultra wideband system is an efficient tool for the evaluation for both current and proposed anechoic EMC compliance test chambers.